Choose whether Google may use analytics cookies and measure site interactions. Basic
measurement without analytics cookies is on by default. You can change your choice from the
footer.
Essential
Always on
Required to remember site preferences that you choose to save.
Analytics
Allows analytics cookies and site interaction measurement. Basic Google page measurement
without analytics cookies continues when this is off. Household calculator inputs are
not sent. You can block this Google Analytics measurement on the Privacy Policy page.
May fit: Selected 120 V loads whose running and startup requirements fit the station's ratings.
Consider another setup: Loads requiring 240 V, more than 1,500 W continuous output, or a verified battery expansion option.
Manufacturer research; no hands-on testing. Source records checked on 2026-10-04.
Compare DELTA 3 and Explorer 1000 v2 by continuous AC output, carrying weight, solar input limits, and UPS transfer time, with BLUETTI AC180 as a third reference.
How the options differ
Different households can reach different answers
We compare the US models using their manufacturer specifications and manuals, then interpret the differences for household backup planning. We have not tested either unit. Capacity is nominal battery energy, not measured AC output. We do not rank by commission, current price, star ratings, or advertised boosted-power modes. Per-field source dates appear in the specification table.
Best fit by need
You need 1,800 W continuous output, six AC outlets, or 10 ms transfer: Examine EcoFlow DELTA 3
Its higher continuous AC limit, six receptacles, 500 W solar ceiling, and 10 ms standby transfer suit denser 120 V cord setups.
You prioritize lighter carrying weight (23.8 lb) and slightly higher base Wh (1,070 Wh): Examine Jackery Explorer 1000 v2
When running loads stay below 1,500 W and three AC outlets are sufficient, the Explorer 1000 v2 shaves Nearly 4 lb off the carry weight.
You want 1,152 Wh nominal capacity and do not mind a 35.27 lb unit: Keep BLUETTI AC180 on the shortlist
AC180 offers 1,800 W continuous output and 1,152 Wh capacity in a heavier chassis.
Documented specifications and the older alternative
Manufacturer specifications, not hands-on measurements. Each figure includes its source and
check date. “Not documented” means the reviewed record does not establish the feature.
Compare columns. Swipe or scroll horizontally on smaller screens.
Documented specifications and the older alternative. Manufacturer research only.
Solar input ceiling An input limit, not a promise of real solar production.
500 WExact-model manual (EF-DL-H10-3) specifies 500 W maximum; EcoFlow's product page mixes series-level DELTA 3 Plus details, so confirm the model label before applying this value.Source · checked 2026-10-04 (opens in a new tab)
Expanded capacity Requires the manufacturer's compatible extra batteries, sold separately.
Not documentedManufacturer lists compatible extra batteries and markets expansion up to 5 kWh, but this record does not establish an exact Wh ceiling for the standalone DELTA 3 configuration.Source · checked 2026-10-04 (opens in a new tab)
Not documentedManufacturer says external batteries can charge the AC180 in Power Bank Mode; its US product FAQ says this is not capacity expansion, so no expanded capacity is counted.Source · checked 2026-10-04 (opens in a new tab)
Criterion-by-criterion record
Compare columns. Swipe or scroll horizontally on smaller screens.
Criterion
Why it matters
EcoFlow DELTA 3
Jackery Explorer 1000 v2
Continuous AC output and receptacles
Simultaneous appliance running watts and plug count determine what can stay connected at once.
1,800 W continuous AC output across six 120 V receptacles, with a separate 3,600 W surge figure in the US manual.
1,500 W continuous AC output across three 120 V receptacles, with a separate 3,000 W instantaneous surge figure.
Nominal energy and carrying weight
Slight differences in watt-hours trade off against carrying weight on stairs or between rooms.
1,024 Wh nominal LFP capacity at approximately 27.6 lb.
1,070 Wh nominal LiFePO4 capacity at approximately 23.8 lb (10.8 kg).
Solar input and expansion
Determines how fast panels can replenish the battery under ideal sun and whether extra batteries are supported.
500 W documented solar-input ceiling on the base EF-DL-H10-3 manual; compatible extra-battery options exist in the EcoFlow family.
400 W documented solar-input ceiling; Jackery states this model does not support expansion battery packs.
Transfer time for pass-through loads
Routers, desktops, and electronics vary in how many milliseconds of power interruption they tolerate.
10 ms documented standby UPS transfer time in the US manual (not 0 ms switching).
20 ms documented battery-mode switching time in the JE-1000D manual (not a 0 ms UPS).
Before you order
Match the unit to your actual load
Write down simultaneous running watts, the largest startup demand, and measured daily
watt-hours. A larger Wh number does not raise the output limit.
Check the exact US model and bundle. Panels, expansion batteries, and charging cables may
be sold separately.
Read the seller, return, and warranty terms for the listing you select. A manufacturer
specification is not proof that every marketplace bundle is equivalent.
Plan a test with your actual equipment before relying on it. Neither a brief UPS transfer
time nor an advertised runtime guarantees compatibility with critical equipment.
The base DELTA 3 is a 1,024 Wh, 1,800 W portable station for selected 120 V essentials. Start with the exact model: DELTA 3, DELTA 3 Plus, and other variants do not share every charging specification.
Nominal capacity
1,024 Wh
Continuous AC output
1,800 W
Base-unit weight
27.6 lb
May fit when
Selected 120 V essentials after checking running watts, startup demand, and daily energy.
Households that need a portable unit and can recharge between interruptions.
Readers comparing documented transfer behavior with their actual equipment requirements.
Consider another setup when
Loads requiring 240 V or more than the continuous output rating.
Long outages without sufficient battery capacity or a dependable recharge plan.
A different variant if your charging requirement exceeds the base model’s documented solar input.
Source records checked on 2026-10-04 for the displayed figures. They are not hands-on
test results. Confirm the exact model, connections, and load requirements before buying.
The Explorer 1000 v2 is a 1,070 Wh, 1,500 W portable station for selected 120 V essentials. Its current U.S. support record specifies 400 W maximum solar input, no battery-pack expansion, and UPS switching within 20 ms.
Nominal capacity
1,070 Wh
Continuous AC output
1,500 W
Base-unit weight
23.8 lb
May fit when
Selected 120 V loads whose running and startup requirements fit the station's ratings.
Households that can recharge the station between interruptions or have a compatible solar plan within the 400 W input limit.
Readers comparing about one kilowatt-hour of base capacity with other portable stations.
Consider another setup when
Loads requiring 240 V, more than 1,500 W continuous output, or a verified battery expansion option.
Equipment that cannot tolerate a UPS transfer interval of up to 20 ms.
Long outages where measured daily energy exceeds the station's realistic delivered capacity and no recharge plan is available.
Source records checked on 2026-10-04 for the displayed figures. They are not hands-on
test results. Confirm the exact model, connections, and load requirements before buying.
The AC180 is a roughly one-kilowatt-hour, 120 V portable battery with 1,800 W continuous output and a documented UPS switching figure of 20 ms or less. Its slightly higher nominal capacity than the DELTA 2 comes with a heavier listed base-unit weight and no directly attached expansion capacity verified in this source record. It remains an older-model alternative to Elite 100 V2.