Calculators Winter heating & fuel safety

How much fuel, battery energy, and ventilation does my winter backup heater need?

The Quick Answer: Running a 9,000 BTU/hr indoor-rated propane heater for 16 hours per day across a 72-hour blackout consumes 20.0 pounds of propane (20 disposable 1 lb cylinders or one 20 lb outdoor tank), whereas a direct-vent 22,000 BTU/hr fuel-oil heater burns roughly 6.7 gallons (25 L) of No. 1 fuel oil and 2,043 Wh of battery backup. Select your heating method, daily runtime, and duration below to size your fuel and ventilation plan.

Select your backup heating system and schedule

Running 16 hrs/day (shutting off unvented combustion heaters before sleeping) saves 33% fuel

Single closed room (~250–350 sq ft / 23–32 m²) vs. whole home (~1,800 sq ft / 167 m²)

Primary Fuel Needed 20.0 lbs Propane 20x 1-lb cans (or 1.0x 20-lb tank)
Battery Energy Needed 0 Wh 100% non-electric
Thermal Output 9,000 BTU/hr 48 total run hours
Ventilation & CO Rule 9 sq in Gap Digital CO alarm mandatory
Loading system-specific carbon monoxide and fuel safety guidance...

Plan first. Buy what is missing.

Compare indoor-safe propane heaters, digital CO monitors, and ambient temperature sensors

Any combustion backup heater requires working battery-powered carbon monoxide alarms on every level and outside sleeping areas. Check what your household already owns before buying new gear.

4,000 / 9,000 BTU/hr Heat output

Mr. Heater Portable Buddy (MH9BX)

Stated heating area
225 sq ft

Check first: Unventilated rooms or unattended overnight sleep — active combustion heaters must stay attended and require fresh-air ventilation.

More specifications & fit

A compact 4,000 / 9,000 BTU/hr dual-setting indoor-safe emergency propane heater rated for up to 225 sq ft, featuring an Oxygen Depletion Sensor (ODS) and tip-over shutoff at 10.6 lb bare weight.

Heat output
4,000 / 9,000 BTU/hr

Unventilated rooms or unattended overnight sleep — active combustion heaters must stay attended and require fresh-air ventilation.

Read the fit and limitations
120V AC plug-in with 9V alkaline battery backup Power source

Check first: Relying solely on this plug-in unit to detect propane or natural gas during a blackout — Kidde specifies that on 9 V battery backup, the KN-COEG-3 monitors CO only to conserve battery life.

More specifications & fit

A UL 2034 / UL 1484 plug-in 3-in-1 digital alarm monitoring carbon monoxide (CO), natural gas (methane), and propane at 85 dB, backed by a 9 V alkaline battery for outage CO continuity.

Gases detected
Carbon Monoxide (CO), Natural Gas (Methane), and Propane
Power source
120V AC plug-in with 9V alkaline battery backup
Digital display
Digital concentration readout (PPM for CO, % LEL for Gas)

Relying solely on this plug-in unit to detect propane or natural gas during a blackout — Kidde specifies that on 9 V battery backup, the KN-COEG-3 monitors CO only to conserve battery life.

Read the fit and limitations
Temperature and relative humidity, sampled once per minute Measurements

Check first: Remote alerts or monitoring when away, unless you also plan for the optional G1 Gateway and internet access.

More specifications & fit

The HT.w logs temperature and humidity locally over Bluetooth. Add SensorPush’s G1 WiFi Gateway only if remote access when away from the sensor matters and a WiFi connection is available.

Measurements
Temperature and relative humidity, sampled once per minute
Water resistance
Splash- and rain-resistant design with sensor membrane and O-ring seals
Storage and battery
45 days of onboard data storage; typical battery life over 2 years

Remote alerts or monitoring when away, unless you also plan for the optional G1 Gateway and internet access.

Read the fit and limitations

Keep your plan useful.

Get occasional preparedness updates. Your calculator inputs and results stay on this device; this signs you up for the newsletter.

Preparedness by email

Sign up for planning updates

Kit provides this form and receives the details you choose to submit. Review its fields and privacy information before signing up.

Loading the sign-up form from Kit.

Isolate one warm core room and verify carbon monoxide protection

During a winter power outage, attempting to heat an entire uninsulated house exhausts fuel reserves rapidly. Consolidate household members into one interior room, seal drafts, and match your heating method to strict ventilation and CO monitoring rules.

  1. Select one central room with minimal exterior glazing, hang heavy blankets over open doorways, and keep plumbing cabinet doors open along exterior walls.
  2. Place battery-powered digital carbon monoxide alarms at breathing height inside the heated room and outside sleeping areas before lighting any combustion heater.
  3. Crack a window by at least 1 square inch (6.5 cm²) per 1,000 BTU/hr when operating an unvented indoor-rated propane catalyst heater, and shut it off before sleeping.

Common questions

Can I bring a 20-pound BBQ propane cylinder indoors to run a Buddy heater?

Never store or bring a 20-pound (9.1 kg) liquid propane cylinder indoors. If the pressure relief valve vents inside a living space, heavy propane vapor pools along the floor and creates an explosion hazard. Keep 20-pound cylinders strictly outdoors and pass a regulator-equipped hose through a weatherstripped port, or use disposable 1-pound (454 g) DOT-39 cylinders indoors.

How much fresh air opening does an indoor-safe propane heater require?

ANSI Z21.11.2 and manufacturer manuals specify at least 1 square inch (6.5 cm²) of fresh outdoor air opening per 1,000 BTU/hr of heater input—meaning 4 square inches for 4,000 BTU/hr, 9 square inches for 9,000 BTU/hr, and 18 square inches for 18,000 BTU/hr, paired with a working battery-powered digital carbon monoxide alarm.

Why use an inline fuel filter when connecting a 20-pound hose to a catalyst heater?