Manufacturer research Specifications checked 2026-11-16 US model

Frost King HC30A 30-Foot Automatic Electric Heat Cable

Built-in bimetallic thermostat (turns on at 3°C / 38°F), 7 watts per foot output (210W total), safe installation rules on PEX vs. copper pipes, and overlap fire warnings.

Heated cable length
9.1 Meters (30 Feet) (Available 3ft to 30ft)
Power consumption
210 Watts total (7 Watts per linear foot)
Thermostat activation
Turns ON at 3°C (38°F) / OFF above 10°C (50°F)
See all specifications and sources

Is it right for your household?

Where it fits

Built-in inline thermostat automatically energizes the cable when pipe temperature drops below 3°C (38°F) and shuts off above 10°C (50°F)—protecting water pipes down to -40°C (-40°F).

When to consider another option

If your plumbing layout has complex clusters of valves, elbows, and pressure tanks that require spiral-wrapping or overlapping heat cable—or if you want to use thick closed-cell foam pipe insulation—skip the constant-wattage HC30A and spend 55 USD more for a self-regulating cable (Raychem FrostGuard).

More fit considerations

Other situations to consider

  • Draws 7 watts per linear foot (210W total for the 30-foot HC30A model), allowing a 1,000Wh LFP power station to keep a 30-foot vulnerable pipe run thawed for ~4 hours during a blackout.
  • Because the HC30A is a constant-wattage cable, it MUST be installed straight along the pipe—never spiral-wrapped or overlapped over itself, or it will overheat and melt PEX plastic.

Other reasons to choose a different setup

  • Because the HC30A is a constant-wattage cable, it MUST be installed straight along the pipe—never spiral-wrapped or overlapped over itself, or it will overheat and melt PEX plastic.

Manufacturer specification record · No hands-on testing · Source records checked on 2026-11-16

Engineering overview and primary fit

The Frost King HC30A is a 9.1-meter (30-foot) pre-assembled electric pipe heating cable equipped with an integrated inline thermostat that automatically switches on at 3°C (38°F) and turns off above 10°C (50°F), protecting water-filled metal and plastic pipes from freezing down to -40°C (-40°F). Consuming 7 watts per foot (210W total), it is an affordable, plug-and-play solution for straight pipe runs in unheated crawlspaces, garages, and mobile home skirts—provided you obey its strict straight-run, non-overlapping installation rules.

Verified Hardware Specifications

Specification: Frost King HC30A Data vs. Field Engineering Impact. Heated Cable Length: 9.1 Meters (30 Feet) (Available 3ft to 30ft) vs. Never cut, splice, or shorten a constant-wattage heat cable. Power Consumption: 210 Watts total (7 Watts per linear foot) vs. Draws ~1.75 Amps @ 120V AC; runs ~4 hrs on 1kWh LFP battery. Thermostat Activation: Turns ON at 3°C (38°F) / OFF above 10°C (50°F) vs. Thermostat sensor bulb must press flush against the cold pipe. Compatible Pipe Types: Copper, Galvanized Steel, PEX, CPVC vs. Plastic pipes require aluminum foil wrap first to spread heat. Minimum Freeze Protection: Down to -40°C (-40°F) (with 1/2" fiberglass wrap) vs. Must be covered with UL-rated fiberglass insulation over cable.

Critical Installation Rules (Preventing Melting & Fire)

1. Never Overlap, Cross, or Spiral-Wrap Constant-Wattage Cable: Unlike self-regulating polymer cables (such as Raychem FrostGuard), the HC30A uses fixed-resistance heating wire. If two sections of cable cross over each other, heat concentrates at the crossing point and melts through the PVC jacket and PEX pipe wall. Always run the cable straight along the bottom side of the pipe. 2. Strap the Thermostat Bulb Tightly Against the Coldest Pipe Section: The inline black thermostat module *must* be taped flush against the bare pipe surface (not hanging in mid-air) so it accurately reads pipe temperature rather than warmer ambient air. 3. Wrap PEX/CPVC Pipes in Aluminum Foil Tape First: Spiral-wrap plastic pipes with 2-inch HVAC aluminum foil tape before attaching the heat cable so heat conducts evenly all the way around the plastic tube. 4. Use Only Fiberglass Pipe Insulation Over the Cable: Slide a maximum of 13mm (1/2-inch) fiberglass pipe wrap over the pipe and cable—never wrap thick closed-cell rubber foam or vinyl tape over a constant-wattage cable, which can trap excess heat.

Maintenance & Testing Checklist

• Test the thermostat before installation using ice cubes: Plug the HC30A into a GFCI outlet and hold an ice cube or cold pack against the inline thermostat bulb for 3 minutes—the orange neon indicator light in the plug will illuminate when the internal switch closes at 3°C (38°F). • Plug exclusively into a GFCI-protected receptacle: Required by National Electrical Code (NEC) to trip immediately if moisture or rodent damage breaches the cable insulation.

Specifications & sources

These are manufacturer specifications, not independent performance measurements. Source records checked on 2026-11-16. We have not tested this model hands-on.

Heated cable length

9.1 Meters (30 Feet) (Available 3ft to 30ft)

Checked 2026-11-16. Source for Heated cable length (opens in a new tab)

Power consumption

210 Watts total (7 Watts per linear foot)

Checked 2026-11-16. Source for Power consumption (opens in a new tab)

Thermostat activation

Turns ON at 3°C (38°F) / OFF above 10°C (50°F)

Checked 2026-11-16. Source for Thermostat activation (opens in a new tab)

Compatible pipe types

Copper, Galvanized Steel, PEX, CPVC

Checked 2026-11-16. Source for Compatible pipe types (opens in a new tab)

Minimum freeze protection

Down to -40°C (-40°F) (with 1/2" fiberglass wrap)

Checked 2026-11-16. Source for Minimum freeze protection (opens in a new tab)

Research notes & original documents