Manufacturer research Specifications checked 2026-11-16 US model
YoLink FlowSmart All-in-One Battery-Backed Ultrasonic Water Meter & Shutoff Valve
Technical audit of the only inline ultrasonic smart water meter and motorized shutoff valve engineered to run 10+ years on internal battery power.
- Flow sensor technology
- Transit-Time Ultrasonic
- Valve body sizes
- Lead-Free 304 Stainless Steel (3/4" & 1")
- Battery lifespan
- 10+ Years (Internal Industrial Lithium)
Is it right for your household?
Combines a zero-moving-parts ultrasonic flow meter, stainless-steel motorized ball valve, and 10-year internal battery in an IP68 submersible housing.
To achieve a 10-year internal battery life, FlowSmart samples ultrasonic flow periodically rather than running continuous 240Hz pressure-wave sweeps like the AC-powered Phyn Plus. If your primary goal is catching 1-drop-per-minute pinhole leaks behind drywall, choose Phyn Plus on a UPS; if your priority is total blackout independence and hard-water durability, choose YoLink FlowSmart.
More fit considerations
Other situations to consider
- Requires zero 110V AC outlets—making it ideal for underground meter vaults, unpowered crawlspaces, and blackout-resilient homes.
- Shuts off automatically on high GPM bursts, sustained flow duration limits, or direct 915MHz LoRa Control-D2D floor sensor alerts.
Other reasons to choose a different setup
- Shuts off automatically on high GPM bursts, sustained flow duration limits, or direct 915MHz LoRa Control-D2D floor sensor alerts.
Manufacturer specification record · No hands-on testing · Source records checked on 2026-11-16
Engineering overview and primary fit
The YoLink FlowSmart All-in-One eliminates the biggest vulnerability of inline smart water shutoff valves: electrical grid dependency. By uniting an unobstructed ultrasonic transit-time flow sensor, a lead-free stainless-steel motorized ball valve, a 915MHz LoRa transceiver, and an industrial lithium battery pack rated for 10+ years, FlowSmart requires no electrician to wire a nearby 110V AC outlet and continues detecting bursts and closing your water main during multi-day power and internet blackouts.
Verified Hardware Specifications
Specification: YoLink FlowSmart Data vs. Field Engineering Impact. Flow Sensor Technology: Transit-Time Ultrasonic vs. Zero moving impeller parts to jam in hard water (>12 gpg). Valve Body & Sizes: Lead-Free 304 Stainless Steel (3/4" & 1") vs. Superior corrosion and burst resistance vs. plastic bodies. Battery Lifespan: 10+ Years (Internal Industrial Lithium) vs. Zero AC outlet needed; 100% active during grid outages. Ingress Protection: IP68 Submersible vs. Can be installed inside underground curb meter pits that flood. Shutoff Triggers: Max GPM, Continuous Duration, D2D Sensors vs. Stops both running toilets/burst pipes and wet-floor leaks.
Optimal Configuration Settings
1. Continuous Flow Timeout (45–60 Minutes): Set FlowSmart to automatically close if water flows uninterrupted for more than 45 minutes. This catches stuck toilet flappers, outdoor hoses left running, and slab leaks without interrupting normal showers or laundry cycles. 2. Maximum Flow Rate Cap (12–15 GPM): Any flow above 15 GPM in a standard single-family home indicates a sheared supply pipe or ruptured water heater line; set an instant 10-second shutoff above this threshold. 3. Hardware Control-D2D Pairing: Pair all indoor floor leak sensors directly to the FlowSmart valve so wet-floor events trigger closure in under 4 seconds even if Wi-Fi and the YoLink Hub are offline.
Installation Checklist
• Install inline isolation ball valves: Place manual brass ball valves upstream and downstream of the FlowSmart body for easy future servicing. • Verify flow arrow direction: Align the cast arrow on the stainless housing with the direction of incoming municipal water flow so ultrasonic transit-time readings stay accurate.
Specifications & sources
These are manufacturer specifications, not independent performance measurements. Source records checked on 2026-11-16. We have not tested this model hands-on.
- Flow sensor technology
-
Transit-Time Ultrasonic
Checked 2026-11-16. Source for Flow sensor technology (opens in a new tab)
- Valve body sizes
-
Lead-Free 304 Stainless Steel (3/4" & 1")
Checked 2026-11-16. Source for Valve body sizes (opens in a new tab)
- Battery lifespan
-
10+ Years (Internal Industrial Lithium)
Checked 2026-11-16. Source for Battery lifespan (opens in a new tab)
- Ingress protection
-
IP68 Submersible
Checked 2026-11-16. Source for Ingress protection (opens in a new tab)
- Shutoff triggers
-
Max GPM, Continuous Duration, D2D Sensors