Manufacturer research Specifications checked 2026-10-24 US model

EcoFlow DELTA 3 Plus

The DELTA 3 Plus is a 1,024Wh, 1,800W U.S. station with a 1,000W maximum solar input and documented 10ms transfer. Its 12.5kg carrying weight and automatic AC timeout behavior matter alongside output; check exact device compatibility and refrigeration settings before relying on it.

See all specifications and sources

Is it right for your household?

Where it fits

Selected 120V appliances within 1,800W continuous output after starting demand is checked.

When to consider another option

240V loads or use cases requiring 2,200W ordinary AC output.

More fit considerations

Other situations to consider

  • Households that can make use of the documented 1,000W solar ceiling with a compatible array.
  • A medium-capacity unit where portability matters more than a heavy whole-home class station.

Other reasons to choose a different setup

  • Intermittent critical refrigeration without a plan to manage the AC timeout and monitor battery charge.
  • Life-sustaining medical devices or equipment requiring zero-ms transfer.

Manufacturer specification record · No hands-on testing · Source records checked on 2026-10-24

Use the exact EF-DL-H10-4 manual

This guide is for U.S. DELTA 3 Plus, model EF-DL-H10-4: 1,024Wh LFP, 1,800W rated AC output, 3,600W surge and 120V output. It is not the base DELTA 3 or DELTA 3 Classic. Confirm the name and manual together; X-Boost or heating-load claims do not change the regular rated output.

Check startup, watts and stored energy separately

The 1,024Wh rating describes nominal stored energy; conversion losses and inverter overhead reduce what AC devices receive. The 1,800W rating limits simultaneous ordinary output. A 3,600W surge figure does not establish the startup duration a compressor needs. List device labels, duty cycles and startup needs, then verify the combination before outage use.

Match the complete solar array to both input limits

The manual lists up to 1,000W solar input over two ports and model-specific voltage/current limits for each. Check panel Voc, Imp, temperature effects and wiring arrangement against the port limits. Total panel nameplate watts alone do not show compatibility or expected charge rate; shade, orientation and weather change production.

Set up refrigeration behavior before an outage

EcoFlow warns that intermittent loads such as refrigerators can trigger an AC timeout that turns the output off. The manual directs users to set the timeout to Never for such use and to check remaining battery regularly when critical refrigeration is involved. Rehearse the exact refrigerator/station behavior and retain another food-safety plan; this is not a guarantee of continuous cold storage.

Respect transfer and medical-equipment exclusions

The manufacturer documents 10ms standby UPS transfer, not zero-ms switching. The manual expressly says the station is not intended for life-sustaining medical equipment, including med-grade ventilators and hospital-grade CPAP. Do not treat a portability or UPS label as clinical approval; consult the device maker and clinician for any medical power plan.

Specifications & sources

These are manufacturer specifications, not independent performance measurements. Source records checked on 2026-10-24. We have not tested this model hands-on.

Nominal capacity

1,024 Wh

LFP nominal capacity.

Checked 2026-10-24. Source for Nominal capacity (opens in a new tab)

Battery chemistry

LFP

Checked 2026-10-24. Source for Battery chemistry (opens in a new tab)

Continuous AC output

1,800 W

U.S. 120V model.

Checked 2026-10-24. Source for Continuous AC output (opens in a new tab)

Surge output

3,600 W

Surge rating; not a guaranteed compressor-start rating.

Checked 2026-10-24. Source for Surge output (opens in a new tab)

US AC outlet count

6 outlets

U.S. manual EF-DL-H10-4.

Checked 2026-10-24. Source for US AC outlet count (opens in a new tab)

240 V AC output

No

Standalone U.S. unit AC output is 120V.

Checked 2026-10-24. Source for 240 V AC output (opens in a new tab)

Maximum solar input

1,000 W

Two solar input ports with combined maximum; check voltage/current limits per port.

Checked 2026-10-24. Source for Maximum solar input (opens in a new tab)

Maximum documented expanded capacity

Not verified in this source record

Manufacturer describes compatible expansion range but an exact standalone-compatible maximum was not fully reconciled in this scoped check.

Checked 2026-10-24. Source for Maximum documented expanded capacity (opens in a new tab)

Transfer / switching time

10 ms

Standby UPS transfer 10ms; not zero-ms.

Checked 2026-10-24. Source for Transfer / switching time (opens in a new tab)

Base-unit weight

27.56 lb

12.5kg converted to lb.

Checked 2026-10-24. Source for Base-unit weight (opens in a new tab)

Listed warranty term

5 years

Manufacturer U.S. product page lists five-year warranty.

Checked 2026-10-24. Source for Listed warranty term (opens in a new tab)

Research notes & original documents